[vc_row margin_top=”0″ margin_bottom=”20″][vc_column][vc_column_text]Applicator:            Resin Surfaces Ltd

Main Contractor:     Hawkins Construction

Design Consultant: Boffa Miskell[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”2/3″][vc_column_text]In readiness for the arrival of 2011–12 Volvo Ocean Race fleet into Auckland, 1,700m2 of Ballatini-Strada retro-reflective surfacing was applied to the pedestrian surfaces on Te Wero Island and Bascule bridge that provide access to Karanga Plaza and the Viaduct Events Centre at the Viaduct Harbour on Auckland’s Waterfront.

 

Ballatini-Strada is a coloured surfacing that uses coloured glass beads as aggregate. A combination of Blue, Orange, Green and White retro-reflective Ballatini-Strada surface was laid.

This project was undertaken and completed by Resin Surfaces.

Contact Mike Coote mob 027 738 5952, or

Email:

mi**@re***********.nz











.[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_single_image image=”129″ img_size=”large”][/vc_column][/vc_row][vc_row][vc_column][vc_column_text]Completion date: February 2012[/vc_column_text][/vc_column][/vc_row]

[vc_row margin_top=”0″ margin_bottom=”20″ padding_left=”40″ padding_right=”40″ bg_position=”top” bg_repeat=”no-repeat” bg_cover=”false” bg_attachment=”false” padding_top=”40″ padding_bottom=”40″ parallax_speed=”0.1″][vc_column width=”1/1″][vc_column_text]Project: Insulation of Tank T-101, Paritutu Tank Farm, Taranaki
Environment: Coastal, atmospheric corrosivity category E-M
Owner: Shell Todd Oil Services
Products: Jotun Tankguard Storage / Endurathane SR52 / Enduracryl PUR Coating
Applicator: Polymer Group Ltd Contracting and Highgrade Coatings Ltd[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column width=”2/3″][vc_column_text]Tank T-101 is a mild steel tank with floating lid. The tank is heated to prevent the build-up of waxes on the tank walls that could cause the floating lid to seize up.

The tank was stripped of its original thermal insulation and inspected for corrosion under insulation (CUI). It was then cleaned and abrasive blasted and Jotun Tankguard Storage was applied. Endurathane SR52 polyisocyanurate foam was spray applied . Finally the foam insulation was sealed and protected with Enduracryl PUR coating.

Jotun Tankguard Storage was recommended as the coating under insulation to prevent CUI.[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_single_image image=”463″ alignment=”center” border_color=”grey” img_link_target=”_self” img_size=”full”][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]Completion date: March 2012[/vc_column_text][/vc_column][/vc_row]